Home Exhibitions and Congresses Equipments and Services Technical Specifications
Technical Specifications PDF Print E-mail

 

In an exhibition and congress centre built from scratch to the purposes it was designed for, nothing is left to hazard. All infra structure is equipped with modern and sophisticated telecommunication systems, tv closed circuits, optical fibre structural cables, system for technical management of the building, etc.

 

Ursa Major Auditorium

  • 2 Technical cabins
  • Electro-mechanic front projection screen, 8 x 4 metres
  • Retro-projection screen of 4 x 3 m
  • Video and audio input/output to broadcast via cable TV, cable modem, codec or ISDN
  • Load/unload dock direct to the stage allowing access to vehicles up to 3.5 tons
  • Access ramp to the stage for low profile vehicles
  • Corridor for transmission cables using links until the top of the building, equidistant 100 metres
  • Philips DCN simultaneous translation system for 10/12 languages, with infrared transmission
  • 12-rod system for scene and lights
  • 8 lateral light towers
  • 2 front light rods
  • Stand GSX 2 x 72 ways computerized stage illuminating system
  • Room illumination by 10 Philips DFS XR20 dimmers controlled by régies and by infrared system from the room
  • Air conditioning

Communication:

  • 60 phone pairs
  • ISDN lines
  • Links up to 1.24 Mb/s
  • Category 5 structured network, protocol T586A at 10/100 MB and optical fibre backbone, with Madinfo local Internet server with 2 MB/s link to Telepac.

Ursa Minor Auditorium

  • 3 Technical cabins
  • Front projection screen with 4 x 3 m
  • Retro-projection screen with 4 x 3 m
  • Video and audio input/output for broadcast via Cable TV, Cable modem, Codec or ISDN
  • Corridor for transmission cables using links until the top of the building, equidistant 100 metres
  • Philips DCN simultaneous translation system for 6 languages, with infrared transmission
  • Room illumination by 10 Philips DFS XR20 dimmers controlled by régies and by infrared system from the room
  • Air conditioning

Communications:

  • 60 phone pairs
  • ISDN lines
  • Links up to 1.24 Mb/s
  • Category 5 structured network, protocol T586A at 10/100 MB and optical fibre backbone, with Madinfo local Internet server with 2 MB/s link to Telepac.

Cassiopeia room

  • Front projection screen with 3 x 2.5 m or 4 x 3 m
  • Retro-projection screen with 3 x 2.5 m or 4 x 3 m
  • Room illumination by 10 Philips DFS XR20 dimmers controlled by régies and by infrared system from the room
  • Air conditioning

Communications:

  • 120 phone pairs
  • ISDN lines
  • Links up to 1.24 Mb/s
  • Category 5 structured network, protocol T586A at 10/100 MB and optical fibre backbone, with Madinfo local Internet server with 2 MB/s link to Telepac.

Andromeda room

  • Front projection screen with 3 x 2.5 m or 4 x 3 m
  • Room illumination by 10 Philips DFS XR20 dimmers controlled by régies and by infrared system from the room
  • Air conditioning

Communications:

  • 120 phone pairs
  • ISDN lines
  • Links up to 1.24 Mb/s
  • Category 5 structured network, protocol T586A at 10/100 MB and optical fibre backbone, with Madinfo local Internet server with 2 MB/s link to Telepac.

Pegasus room

  • Front projection screen with 3 x 2.5 m or 4 x 3 m
  • Room illumination by 10 Philips DFS XR20 dimmers controlled by régies and by infrared system from the room
  • Air conditioning

Communications:

  • 120 phone pairs
  • ISDN lines
  • Links up to 1.24 Mb/s
  • Category 5 structured network, protocol T586A at 10/100 MB and optical fibre backbone, with Madinfo local Internet server with 2 MB/s link to Telepac.

Exhibition Centre - Pavilions A and B

  • Area of 2,500 sq m (38 x 72 m) each Pavilion
  • Floor loads of 10 and 50 kn sqm
  • 23 Drinking water supply spots at 6 Kg sqm in each Pavilion
  • 23 sewer spots in each Pavilion
  • 276 lines category 5 at 10/100 Mb/s in each Pavilion
  • 8 Fibres at the backbone
  • 276 phone lines

Reverberation characteristics - Pavilion A

Position

Reverberation times (s)

125

250

500

1000

2000

4000

Average reverberation characteristic

2.8 s

2.2 s

1.8 s

1.9 s

2.0 s

1.9 s

 

Reverberation characteristics - Pavilion B

Position

Reverberation times (s)

125

250

500

1000

2000

4000

Average reverberation characteristic

4.6 s

3.6 s

3.1 s

3.2 s

2.9 s

2.4 s

 

reverb_tab_e_graf_ingl